M22-K10 – Contact block, Screw terminals, Front fixing, 1 NO contact, 24 V 3 A, 220 V 230 V 240 V 6 A
EATON
216376 M22-K10
SUPPLY PROGRAM
Assortment
Accessories
Basic accessory function
Contact elements
accessories
Auxiliary contact
accessories
Normal auxiliary contacts, auxiliary signaling contacts
Standard / Approval
UL / CSA, IEC
Size
NZM1 / 2/3/4
Types of connection
Screw terminals
Type of fastening
Front fixing
Degree of protection
IP20
Connection to SmartWire-DT
no
use with
NZM1 (-4), 2 (-4), 3 (-4), 4 (-4)
PN1 (-4), 2 (-4), 3 (-4)
N (S) 1 (-4), 2 (-4), 3 (-4), 4 (-4)
Contact equipment
NA = norm. open
1 NO contact
Connection type
Single contact
Description of auxiliary contact for HIA release signaling
General “+” trip signaling in the event of tripping by voltage releases, thermal releases, short-circuit releases, and when using a differential protection module for the fault current.
Use with size NZM1, 2, 3 circuit breaker: an auxiliary trip contact can be clipped into the circuit breaker.
Use with size NZM4 circuit breaker: up to two auxiliary release contacts can be clipped into the circuit breaker.
Desired combinations of auxiliary contact types are possible.
Cannot be used in conjunction with PN … switch-disconnector
Marking on the circuit-breaker: HIA
Marking on the FI block: HIAFI.
Using the trip signaling auxiliary contact in the FI block, the opening contact functions as a closing contact and the closing contact as an opening contact.
Description of normal auxiliary contact HIN
Replicate the position of the main contacts Performs signaling and interlocking operations
Use with size NZM1 circuit breaker: a normal auxiliary contact can be clipped into the circuit breaker.
Use with size NZM2 circuit breaker: up to two normal auxiliary contacts can be clipped into the circuit breaker.
Use with size NZM3, 4 circuit breaker: up to three normal auxiliary contacts can be clipped into the circuit breaker.
Desired combinations of auxiliary contact types are possible.
Marking on the switch: HIN
In case of combination with remote control NZM-XR … the installation space on the right for normal auxiliary contacts HIN can only be equipped with single contacts.
Types of connection
Screw terminals
Note
The following applies to the packaging:

M22‐ (C) K…: package = 20 pieces

Note
Clips into the switch:

NZM1: A normal auxiliary contact
NZM2: up to 2 normal auxiliary contacts M22- (C) K …
NZM3: up to 3 normal auxiliary contacts M22- (C) K …
NZM4: up to 3 normal auxiliary contacts M22- (C) K …
Any combinations of auxiliary contact types are possible.

Marking on the switch: HIN

In the case of combinations with NZM-XR… remote control, some flush-mounted units with normal auxiliary contacts can only be equipped with single contacts.

NZM2: left-hand built-in unit with normal auxiliary contacts equipped with single contact only.

NZM3: all flush-mounted units with normal auxiliary contacts equipped with single contact only.

NZM4: right-hand built-in unit with normal auxiliary contacts equipped with single contact only.

TECHNICAL DATA
Generality
Compliance with standards
IEC 60947-5-1
Mechanical life [Operations]
> 5 x 10 6
Operating frequency [man / h]
≦ 3600
Actuation force
≦ 5 NET
Torque of the drive (screw terminals)
≦ 0.8 Nm
Degree of protection
IP20
Suitability for climates
Humid heat, constant, according to IEC 60068-2-78
Humid heat, cyclic according to IEC 60068-2-30
Room temperature
per day
-25 – +70 ° C
Shock resistance according to IEC 60068-2-27

Shock duration 11 ms, half wave
> 30 g
Connection sections
Stiff
0.75 – 2.5 mm 2
Connection sections
Flexible
0.5 – 2.5 mm 2
Connection sections
Flexible with ferrule
0.5 – 1.5 mm 2
Relay contacts
Rated impulse withstand voltage [U imp ]
6000 V AC
Rated insulation voltage [U i ]
500 V
Overvoltage category / pollution degree
III / 3
Safety against false maneuvers
at 24 V DC / 5 mA [H F ]
<10 - 7, <1 interruption out of 10 7 maneuvers Error frequency Safety against false maneuvers at 5 V DC / 1 mA [H F ] <5 x 10 - 6 (dh 1 interruption on 5 x 106 operations) Error frequency Max. Short-circuit protection device without fuse PKZM0-10 / FAZ-B6 / 1 Type Max. Short-circuit protection device Fuse [gG / gL] 10 A Breaking power Rated operational current [I e ] AC-15 115 V [I e ] 6 A Rated operational current [I e ] AC-15 220 V 230 V 240 V [I e ] 6 A Rated operational current [I e ] AC-15 380 V 400 V 415 V [I e ] 4 A Rated operational current [I e ] AC-15 500 V [I e ] 2 A Rated operational current [I e ] DC-13 24 V [I e ] 3 A Rated operational current [I e ] DC-13 42 V [I e ] 1.7 A Rated operational current [I e ] DC-13 60 V [I e ] 1.2 A Rated operational current [I e ] DC-13 110 V [I e ] 0.6 A Rated operational current [I e ] DC-13 220 V [I e ] 0.3 A Durability, electrical AC-15 230 V / 0.5 A [Operations] 1.6 x 10 6 Durability, electrical AC-15 230 V / 1.0 A [Operations] 1 x 10 6 Durability, electrical AC-15 230 V / 3.0 A [Operations] 0.7 x 10 6 Durability, electrical DC-13 12 V / 2.8 A [Operations] 1.2 x 10 6 Auxiliary contacts Rated operational voltage [U e ] Rated operational voltage [U e ] 500 V AC Rated operational voltage [U e ] Rated operational voltage max. [EU] 220 V DC Conventional thermal current in free air [I t h =Ie] 4 A Rated operational current [I e ] Different rated operational currents when used as an auxiliary contact for the NZM circuit breaker M22- (C) K10 (01) M22-CK11 (02) (20) XHIV bei AC = 50/60 Hz Bemessungsbetriebsstrom AC-15 115 V Ie TO 4 4 4 230 V Ie TO 4 4 4 400 V Ie TO 2 - 2 500 V Ie TO 1 - 1 DC-13 24 V Ie TO 3 3 3 42 V Ie TO 1.7 1 1.5 60 V Ie TO 1.2 0.8 0.8 110 V Ie TO 0.6 0.5 0.5 220 V Ie TO 0.3 0.2 0.2 Short circuit protection Max fuse 10 A dd / gL Short circuit protection circuit breaker max. FAZ-B6 / B1 A Switching times HIV lead time with respect to main contacts at insertion and disconnection (switching times with manual control): NZM1, PN1, N (S) 1: approx. 20 ms NZM2, PN2, N (S) 2: approx. 20 ms NZM3, PN3, N (S) 3: approx. 20 ms NZM4, N (S) 4: approx. 90 ms, HIV does not anticipate switching off . Connection sections Rigid / flexible, with tip 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm 2 UL / CSA Rated operational current [I e ] 5 A - 600 V AC 1 A - 250 V DC A Other technical data (browsable catalog) Maximum equipment and location of interior accessories DESIGN VERIFICATIONS ACCORDING TO IEC / EN 61439 Technical data for design checks Rated operational current for dissipation data [I n ] 6 A Dissipation per pole, as a function of the current [P vid ] 0.11 W Device dissipation, depending on the current [P vid ] 0 W Static dissipation, independent of the current [P vs ] 0 W Dissipation power [P ve ] 0 W Ambient service temperature min. -25 ° C Ambient service temperature max. +70 ° C IEC / EN 61439 design verifications 10.2 Suitability of materials and components 10.2.2 Corrosion resistance The requirements of the product standard are met. 10.2 Suitability of materials and components 10.2.3.1 Resistance of the enclosure to heat The requirements of the product standard are met. 10.2 Suitability of materials and components 10.2.3.2 Resistance of insulating materials to normal heat levels The requirements of the product standard are met. 10.2 Suitability of materials and components 10.2.3.3 Resistance of insulating materials to extraordinary heat levels The requirements of the product standard are met. 10.2 Suitability of materials and components 10.2.4 Resistance to UV radiation The requirements of the product standard are met. 10.2 Suitability of materials and components 10.2.5 Lifting Not relevant as the whole electrical panel needs to be evaluated. 10.2 Suitability of materials and components 10.2.6 Impact test Not relevant as the whole electrical panel needs to be evaluated. 10.2 Suitability of materials and components 10.2.7 Lettering The requirements of the product standard are met. 10.3 Degree of protection of the enclosures Not relevant as the whole electrical panel needs to be evaluated. 10.4 Air and surface dispersion routes The requirements of the product standard are met. 10.5 Protection against electric shock Not relevant as the whole electrical panel needs to be evaluated. 10.6 Flush mounting of devices Not relevant as the whole electrical panel needs to be evaluated. 10.7 Internal circuits and connections It is the responsibility of the manufacturer of the electrical panel. 10.8 Connections for conductors introduced from outside It is the responsibility of the manufacturer of the electrical panel. 10.9 Insulation characteristics 10.9.2 Dielectric strength at mains frequency It is the responsibility of the manufacturer of the electrical panel. 10.9 Insulation characteristics 10.9.3 Impulse withstand voltage It is the responsibility of the manufacturer of the electrical panel. 10.9 Insulation characteristics 10.9.4 Verification of enclosures in insulating material It is the responsibility of the manufacturer of the electrical panel. 10.10 Heating The superheat calculation is the responsibility of the electrical panel builder. Eaton provides equipment dissipation data. 10.11 Resistance to short circuit It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment. 10.12 EMC It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment. 10.13 Mechanical function For the device, the requirements are met if the information in the installation instructions (IL) is observed. TECHNICAL DATA ACCORDING TO ETIM 8.0 low voltage electrical appliances (EG000017) / Auxiliary contacts (EC000041) Technique Of Ar., Electr., Energy, Tecn. Switchgear, Network & Mains Process / Low Voltage Switching Technology / Component For Low Voltage Switching Technology / Auxiliary Switch Block (ecl@ss10.0.1-27-37-13-02 [AKN342013]) number of reversing contacts 0 number of closing contacts 1 number of rest contacts 0 number of signal switches 0 rated operating current Ie for AC-15, 230 V 6 A making the electrical connection screw connection Typology insertable and integrable Mounting type front fixing lamp holder without APPROVALS Product Standards IEC / EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Degree of Protection UL / CSA Type: -