1405882 – PHOENIX

Network cable – VS-IP20-IP20-93E-LI / 1.0
1405882 PHOENIX
Network cable, Ethernet CAT5, 4-pin, PUR, sea blue RAL 5021, RJ45 straight plug, to RJ45 straight plug, cable length: 1 m
Product type Pre-assembled data cable
No. poles 4
Number of cable outlets 1
Number of slots 1
Shielded Yes
Cable outlet right
Signal type / category Ethernet CAT5 (IEC 11801:2002)
Transmission medium Copper
Combustion class according to UL 94 V2
Maneuver cycles ≥ 750
Connection 1
Guy Straight male RJ45
Connection 2
Guy Straight male RJ45
Cable length 1 m
Line weight 42 kg/km
UL AWM Style 20963 (80 °C / 30 V)
No. poles 4
Shielded Yes
Cable type Flexible Ethernet CAT5, 2-pair [93E]
Runtime 5,3 ns/m
Line signal conductor structure 7x 0,16 mm
AWG signal line 26
Conductor cross section 2x 2x 0,14 mm²
Wire diameter with insulating sheath 0,98 mm
Conductor outer diameter 6,4 mm ±0,2 mm
Outer sheath, material EVEN THOUGH
Outer sheath, color sea blue RAL 5021
Conductor material Filo Cu nudo
Material, wire insulation Expanded PE
Single conductor, color white / orange-orange, white / green-green
Wall thickness outer sheath 1,2 mm
Twisting in pairs 2 conductors in pairs
Whole stranding 2 paisa with 2 fillers towards the core
Optical shield cover 70%
Insulation resistance ≥ 500 MΩ*km
Coupling resistance ≤ 100,00 mΩ/m (con 10 MHz)
Resistance of the twisted pair ≤ 290.00 Ω/km
Characteristic impedance 100 Ω ±5 Ω (con 100 MHz)
Line capacity ca. 45 nF/km (at 1 kHz)
Rated cable voltage ≤ 100 V (Peak value, not for high currents)
Thread / thread test tension 700 V (50 Hz, 1 min.)
Test wire / shield voltage 700 V (50 Hz, 1 min.)
Permissible current load of the cable 2 A (according to DIN VDE 0891-1)
Minimum bending radius, fixed 4 x D
Minimum bend radius, flexible 8 x D
Tensile strength ≤ 80 N
Paradiaphonic attenuation (NEXT) 65.3 dB (with 1 MHz)
56.3 dB (with 4 MHz)
50.3 dB (with 10 MHz)
47.2 dB (with 16 MHz)
45.8 dB (with 20 MHz)
42.9 dB (at 31.25 MHz)
38.4 dB (with 62.5 MHz)
35.3 dB (with 100 MHz)
Power-Sum Paraphone Attenuation (PSNEXT) 62.3 dB (with 1 MHz)
53.3 dB (with 4 MHz)
47.3 dB (with 10 MHz)
44.2 dB (with 16 MHz)
42.8 dB (with 20 MHz)
39.9 dB (at 31.25 MHz)
35.4 dB (with 62.5 MHz)
32.3 dB (with 100 MHz)
Return Attenuation (RL) 23 dB (with 4 MHz)
24.1 dB (with 8 MHz)
25 dB (with 10 MHz)
25 dB (with 16 MHz)
25 dB (with 20 MHz)
23.6 dB (at 31.25 MHz)
21.5 dB (with 62.5 MHz)
20.1 dB (with 100 MHz)
Shield attenuation 3.2 dB (with 1 MHz)
6 dB (with 4 MHz)
9.5 dB (with 10 MHz)
12.1 dB (with 16 MHz)
13.6 dB (with 20 MHz)
17.1 dB (at 31.25 MHz)
24.8 dB (with 62.5 MHz)
32 dB (with 100 MHz)
Absence of halogens a norma IEC 60754-1
Resistance to flame according to IEC 60332-1-2
according to UL VW1
Resistance to oil according to EN 60811-2-1
Ambient temperature (operation) -40 ° C … 80 ° C (cables, fixed installation)
-20 ° C … 80 ° C (Cables, mobile laying)
Ambient temperature (installation) -20 °C … 80 °C
Line weight 43 kg/km
Cable type Ethernet
Signal type / category Ethernet CAT5 (IEC 11801:2002)
Cable structure 2x2xAWG26/7; SF/UTP
Conductor outer diameter 6,70 mm
Outer sheath, material EVEN THOUGH
Outer sheath, color sea blue RAL 5021
Conductor material Filo Cu nudo
Line signal conductor structure 7x 0,16 mm
AWG signal line 26
Wire diameter with insulating sheath 1 mm
Single conductor, color white-orange, white-green
Minimum bending radius, fixed installation 33.5 mm (cables, fixed installation)
Minimum bending radius, mobile laying 33.5 mm (Cables, mobile laying)
Minimum bending radius, fixed installation 33.5 mm (cables, fixed installation)
Minimum bending radius, mobile laying 33.5 mm (Cables, mobile laying)
Degree of protection IP20
Degree of protection IP20